AIRCO CARBIDE -- ACETYLENE -- 6830-00N043768
===================== Product Identification =====================
Product ID:ACETYLENE
MSDS Date:02/01/1987
FSC:6830
NIIN:00N043768
=== Responsible Party ===
Company Name:AIRCO CARBIDE
Box:10037
City:LOUISVILLE
State:KY
ZIP:40210
Country:US
Info Phone Num:502-423-4400
Emergency Phone Num:502-775-4123;800-424-9300(CHEMTREC)
Preparer's Name:KURT CHAPMAN
CAGE:76624
=== Contractor Identification ===
Company Name:AIRCO CARBIDE
Box:City:LOUISVILLE
State:KY
ZIP:40210
Country:US
Phone:502-423-4400
CAGE:76624
============= Composition/Information on Ingredients =============
Ingred Name:HYDROGEN SULFIDE (SARA III)
CAS:7783-06-4
RTECS #:MX1225000
OSHA PEL:10 PPM;15 PPM STEL
ACGIH TLV:10 PPM;15 PPM STEL
EPA Rpt Qty:100 LBS
DOT Rpt Qty:100 LBS
Ingred Name:AMMONIA
CAS:7664-41-7
RTECS #:BO8750000
OSHA PEL:35 PPM STEL
ACGIH TLV:25 PPM;35 PPM STEL
EPA Rpt Qty:100 LBS
DOT Rpt Qty:100 LBS
Ingred Name:PHOSPHINE
CAS:7803-51-2
RTECS #:SY7525000
OSHA PEL:0.03 PPM;1 PPM STEL
ACGIH TLV:0.03 PPM;1 PPM STEL
EPA Rpt Qty:100 LBS
DOT Rpt Qty:100 LBS
Ingred Name:ARSINE (SARA III)
CAS:7784-42-1
RTECS #:CG6475000
OSHA PEL:0.05 PPM
ACGIH TLV:0.05 PPM
Ingred Name:ACETYLENE
CAS:74-86-2
RTECS #:AO9600000
Fraction by Wt: >98%
OSHA PEL:N/K
ACGIH TLV:SIMPLE ASPHYXIANT
Ingred Name:TRACE IMPURITIES (CONSISTING OF INGREDIENTS 3 - 5)
RTECS #:9999999ZZ
Fraction by Wt: 1-2%
OSHA PEL:N/K
ACGIH TLV:2500 PPM (MFR)
===================== Hazards Identification =====================
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:TLV: ASPHYXIANT HAVING ANESTHETIC
PROPERTIES. ACUTE:SLIGHT INTOXICATION AT 10%. MARKED INTOXICATION
AT 20%. AT 35% CAUSES UNCONSCIOUSNESS IN 5 MINUTES.
CHRONIC:CONTAMINANTS IN GENERATED ACETYLENE CAN HAVE TOXIC EFFECT;
VIA PHOSPINE, ARSINE, HYDROGEN SULFIDE.
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NON-IRRITATING TO SKIN OR MUCOUS
MEMBRANES.
======================= First Aid Measures =======================
First Aid:INGEST:CALL MD IMMEDIATELY . EYES: IMMEDIATELY FLUSH
W/POTABLE WATER FOR A MINIMUM OF 15 MINUTES, SEEK ASSISTANCE FROM
MD . SKIN:FLUSH W/COPIOUS AMOUNTS OF WATER. CALL MD . INHAL:REM OVE
IMMEDIATELY TO UNCONTAMINATED AIR. IF BREATHING HAS STOPPED,
ARTIFICIAL RESPIRATION SHOULD BE APPLIED. CONTACT MD.
===================== Fire Fighting Measures =====================
Flash Point:SUPP DATA
Lower Limits:2.5%
Upper Limits:80%
Extinguishing Media:EXTINGUISH FIRE BY SHUTTING OFF SOURCE OF
ACETYLENE.
Fire Fighting Procedures:USE NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP .
FIRES FROM SM LEAKS IN CNTNRS CAN BE EXTING BY PLUGGING LEAK W/
PUTTY OR SMOTHERING W/FIRE BLANKET. (SUPDAT
Unusual Fire/Explosion Hazard:IN ADMIXTURES CONTAINING MORE THAN 6%
OXYGEN, MAY EXPLODE IN PRESENCE OF IGNITION SOURCE AS LOW AS -40C.
================== Accidental Release Measures ==================
Spill Release Procedures:WARNING! DO NOT ENTER AREA OF HIGH
CONCENTRATION UNTIL FIRST PURGING W/NITROGEN & THEN VENTILATING
W/AIR. ELIMINATE ALL SOURCES OF IGNITION, KEEP PERSONNEL AWAY. ANY
LEAKS OF ACETYLENE PRESENT GREAT D ANGER OF EXPLOSION OR FIRE!
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:STORE IN WELL VENTILATED AREA, AWAY
FROM OXYGEN/NON-FLAMM COMPRESSED GAS CYLS. SHOULD NOT BE
PRESSURIZED >15 PSIG. KEEP CYLINDERS UPRIGHT!
Other Precautions:AVOID SUDDEN SHOCK & ALL SOURCES OF IGNIT INCL STATIC
ELECTRICITY. SHOULD NOT BE W/DRAWN AT RATE GREATER THAN 1/7 OF CYL
CAPACITY PER HR. FASTER W/DRAWAL MAY CARRY OVER ACETONE/MAY CAUSE
STATIC SPKS. KEEP AWAY FROM HEAT, FLAME & (SUPP DATA)
============= Exposure Controls/Personal Protection =============
Respiratory Protection:NIOSH/MSHA APPROVED SELF-CONTAINED BREATHING
APPARATUS FOR EMERGENCY WORK AT HIGH CONCENTRATIONS.
Ventilation:KEEP CONCENTRATION <2500 PPM. USE LOCAL EXHAUST (WELDING &
CUTTING) OR MECH (GENERAL). EXPLOSION-PROOF.
Protective Gloves:LEATHER WHEN WELDING, CUTTING/BRAZING.
Eye Protection:ANSI APPVD CHEM SAFETY GOGGS W/ (SUPDAT)
Other Protective Equipment:PROT CLTHG - ALL COTTON TO PVNT STATIC
BUILD- UP WHILE HNDLG CNTNRS; FLAME RETARDANT FOR WELDING, CUTTING
OR BRAZING.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
FL PT:GASEOUS AT ROOM TEMP. FIRE FIGHT PROC: USE WATER TO COOL
FIRE-EXPOS CYLS. OTHER PREC:SPKS. STORE & USE W/ADEQ VENT. CLOSE
VALVE AFTER EACH USE & WHEN EMPTY. RETURN CYL W/VALVE CLSD. EYE
PROT:FIL TER LENS, SHADE #4 OR DARKER WHEN WELDING OR CUTTING .
================== Physical/Chemical Properties ==================
HCC:G2
Boiling Pt:B.P. Text:-103F,-75C
Vapor Density:0.01
Solubility in Water:1.1 G/ML @ 15.5C
Appearance and Odor:COLORLESS; GARLIC-LIKE ODOR FROM IMPURITIES.
Percent Volatiles by Volume:100
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:NO
FORMS EXPLO ACETYLIDES W/COPPER, SILVER, MERCURY. MIXED W/CHLORINE OR
FLOURINE, CAN EXPLODE ON EXPOS TO SUNLIGHT.
Stability Condition to Avoid:UNSTABLE IN FREE STATE UNDER PRESSURE.
STABLE BELOW 15 PSIG OR IN ACETONE SOLUTION.
Hazardous Decomposition Products:UNDER PRESSURE MAY DECOMPOSE INTO
HYDROGEN & CARBON W/EXPLOSIVE FORCE.
==================== Disposal Considerations ====================
Waste Disposal Methods:DISPOSAL MUST BE I/A/W FEDERAL, STATE & LOCAL
REGULATIONS . IF PRACTICAL, REMOVE CYLINDER TO SAFE, OUTSIDE AREA.
VENT TO ATMOSPHERE AT SLOW RATE. KEEP ALL SOURCES OF IGNITION AWAY.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.