ALTANA INC BYK PHARMACEUTICAL GROUP -- ZINC OXIDE OINTMENT USP -- 6505-00-150-1990
===================== Product Identification =====================
Product ID:ZINC OXIDE OINTMENT USP
MSDS Date:01/28/1986
FSC:6505
NIIN:00-150-1990
=== Responsible Party ===
Company Name:ALTANA INC BYK PHARMACEUTICAL GROUP
Address:60 BAYLIS RD
City:MELVILLE
State:NY
ZIP:11747-3806
Country:US
Info Phone Num:516-454-7692
Emergency Phone Num:516-454-7677
CAGE:60910
=== Contractor Identification ===
Company Name:ALTANA INC BYK PHARMACEUTICAL GROUP
Address:60 BAYLIS RD
Box:City:MELVILLE
State:NY
ZIP:11747-3806
Country:US
Phone:631-454-7677
CAGE:60910
============= Composition/Information on Ingredients =============
Ingred Name:ZINC OXIDE
CAS:1314-13-2
RTECS #:ZH4810000
Fraction by Wt: 20%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:15MG/M3 TDUST/5 FUME
ACGIH TLV:10MG/M3 TDUST; 9293
Ingred Name:PETROLATUM
Fraction by Wt: 60%
Other REC Limits:NONE RECOMMENDED
Ingred Name:MINERAL OIL (EXPOSURE REGULATED AS 'OIL MIST')
CAS:8012-95-1
RTECS #:PY8030000
Fraction by Wt: 15%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:5 MG/M3
ACGIH TLV:5 MG/M3/10 STEL;9293
Ingred Name:WAXES
Fraction by Wt: 5%
Other REC Limits:NONE RECOMMENDED
===================== Hazards Identification =====================
Routes of Entry: Inhalation:NO Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: CONTACT WITH EYES MAY CAUSE
IRRITATION. SWALLOWING MAY CAUSE A LAXATIVE EFFECT TO DIGESTIVE
TRACT. NOT AN INHALATION HEALTH HAZARD UNDER NORMAL CONDITIONS OF
USE. CHRONIC: NONE KNOWN.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:EYES: REDNESS, DISCOMFORT. SWALLOWING:
DIARRHEA.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
======================= First Aid Measures =======================
First Aid:INHALED: MOVE TO FRESH AIR. IF BREATHING DIFFICULT, GIVE
OXYGEN. EYES: FLUSH WITH WATER FOR 15 MINUTES, HOLDING LIDS OPEN.
SEE DOCTOR. SKIN: WASH WITH SOAP AND WATER. INGESTED: INDUCE
VOMITING, IF CON SCIOUS. SEE DOCTOR. IF ANY SYMPTOMS PERSIST, SEE
DOCTOR.
===================== Fire Fighting Measures =====================
Extinguishing Media:FOAM, DRY CHEMICAL, WATER FOG
Fire Fighting Procedures:WEAR SELF-CONTAINED BREATHING APPARATUS AND
BUNKER GEAR.
Unusual Fire/Explosion Hazard:ZINC OXIDE FUMES ARE PRODUCED UNDER FIRE
CONDITIONS.
================== Accidental Release Measures ==================
Spill Release Procedures:ABSORB WITH INERT MATERIAL SUCH AS VERMICULITE
OR SAND AND PLACE IN A CONTAINER FOR LATER DIPOSAL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:KEEP CLOSED AND AWAY FROM EXCESSIVE
HEAT AND OXIDIZING AGENTS. PROTECT AGAINST DAMAGE. STORE IN A COOL,
DRY AREA.
Other Precautions:CONTAINER IS NOT REUSABLE.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:NONE NORMALLY REQUIRED.
Ventilation:USE ADEQUATE MECHANICAL VENTILATION.
Protective Gloves:NONE NORMALLY REQUIRED.
Eye Protection:NONE NORMALLY REQUIRED.
Other Protective Equipment:NONE NORMALLY REQUIRED.
Work Hygienic Practices:WASH HANDS AFTER USE AND BEFORE EATING,
DRINKING, OR SMOKING.
Supplemental Safety and Health
================== Physical/Chemical Properties ==================
HCC:N1
Boiling Pt:B.P. Text:>121F,>49C
Vapor Pres:<1 MM HG
Vapor Density:0 (AIR=1)
Spec Gravity:1.01 (WATER=1)
Evaporation Rate & Reference:0 (METHOD:UNKNOWN)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:WHITE OINTMENT, FAINT ODOR
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
OXIDIZING AGENTS
Stability Condition to Avoid:EXTREME HEAT, OXIDIZING AGENTS
Hazardous Decomposition Products:ZINC OXIDE FUMES, CARBON MONOXIDE
==================== Disposal Considerations ====================
Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH LOCAL, STATE AND
FEDERAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.